State AED Laws · Mississippi

Mississippi AED Laws & Requirements

Mississippi requires AED use to be under the medical control of a Mississippi-licensed physician, with trained users who activate EMS and report each use. Since 2024–2025, every public school must have a cardiac emergency response plan.

Last reviewed November 2026

At a Glance

Mississippi AED Laws at a Glance

Physician oversightA Mississippi-licensed physician must exercise medical control over AED use
TrainingUsers trained in CPR and AED use by AHA, Red Cross, NSC, or another national course
After AED useActivate EMS as soon as possible and report clinical use to the physician
MaintenancePhysician oversight covers maintenance; follow the manufacturer’s instructions
SchoolsCardiac emergency response plans in every public school since 2024–2025
Good SamaritanProtection for good-faith AED use, except gross negligence or willful or wanton misconduct

Mississippi AED Requirements

Under Mississippi Code § 41-60-33, any person may use an AED to try to save a life, subject to these requirements:

  • A Mississippi-licensed physician must exercise medical control over the AED user to ensure compliance with training, EMS notification, and maintenance requirements.
  • The user must be trained in CPR and AED use through the American Heart Association, American Red Cross, National Safety Council, or another nationally recognized course.
  • The AED may not be used in manual mode except under access controls or by appropriately licensed professionals.
  • Anyone who uses an AED must activate EMS as soon as possible and report any clinical use to the licensed physician.

Legal reference: Miss. Code § 41-60-33

A green status indicator does not necessarily confirm that electrode pads are within their expiration date or that every component is ready for emergency use. Routine status checks are not the same as a comprehensive AED inspection. Learn more about onsite AED maintenance and inspections.

Mississippi Good Samaritan Protections

Under Mississippi Code § 73-25-37, a person who in good faith provides emergency care with an AED in accordance with the state’s AED law, acting as a reasonably prudent person would, is protected from civil liability, as is the person responsible for the site who provided for compliance. Protection extends to the authorizing physician, premises owner, purchaser, and CPR/AED trainer. It does not apply to gross negligence or willful or wanton misconduct.

Legal reference: Miss. Code § 73-25-37

Mississippi School Cardiac Emergency Response Plans

Under Mississippi Code § 37-11-87 (Chapter 383, Laws of 2024, effective July 1, 2024), beginning in the 2024–2025 school year each public school must have a cardiac emergency response plan, and schools with athletic programs must also cover athletic practices and events. Plans must, at a minimum:

  • Establish and activate a cardiac emergency response team.
  • Plan AED placement and routine maintenance according to American Heart Association or equivalent guidelines.
  • Provide ongoing CPR and AED training for staff, including licensed coaches, school nurses, and athletic trainers.
  • Include annual drills, integration with local EMS, and annual review.

Legal reference: Miss. Code § 37-11-87

HB 633 (2026): Would have required AEDs on site, or available within three minutes, at all school-sponsored athletic events. It died in committee on February 3, 2026.

See our K–12 school AED programs.

AED Service America Recommendations

Meeting minimum legal requirements is only one part of an effective AED program. AED Service America recommends:

  • Comprehensive onsite AED inspections at least annually.
  • Routine status indicator checks between inspections.
  • Tracking and timely replacement of electrode pads and batteries.
  • Documented maintenance and service records.
  • Monitoring of manufacturer recalls and safety notices.
  • CPR/AED training and documented emergency response procedures. See our AED, CPR & First Aid Training.
  • Prompt corrective action when an AED is out of service.

These are AED Service America’s professional maintenance standards, not additional legal requirements.

FAQ

Frequently Asked Questions About Mississippi AED Laws

Does Mississippi require physician oversight for AEDs?

Yes. A Mississippi-licensed physician must exercise medical control over AED use, covering training, EMS notification, and maintenance.

Does Mississippi require AED training?

Yes. AED users must be trained in CPR and AED use through a nationally recognized course.

Must AED use be reported in Mississippi?

Yes. Anyone who uses an AED must activate EMS as soon as possible and report clinical use to the licensed physician.

Are AEDs required in Mississippi schools?

Every public school must have a cardiac emergency response plan that addresses AED placement and maintenance. A 2026 bill requiring AEDs at all school athletic events did not pass.

Does Mississippi require AED maintenance?

Maintenance falls under the physician’s medical control. AEDs should be maintained according to the manufacturer’s instructions.

Does Mississippi provide Good Samaritan protection for AED use?

Yes, for good-faith use, except for gross negligence or willful or wanton misconduct.

How AED Service America Helps Mississippi Organizations

AED Service America provides nationwide onsite AED maintenance and management, including service coverage throughout Mississippi. Our programs help organizations stay Response-Ready through comprehensive onsite inspections, manufacturer-guideline maintenance, electrode pad and battery management, documented service records, and prompt resolution of equipment issues, backed by a contractual commitment to onsite response within 48 hours for out-of-service AEDs. An AED is only valuable when it is ready to perform in an emergency.