Provincial AED Laws · Manitoba

Manitoba AED Laws & Requirements

Manitoba’s Defibrillator Public Access Act requires AEDs at designated public premises such as schools, arenas, pools, fitness clubs, and airports. Owners must register each AED within 30 days, inspect it monthly, keep inspection records for 12 months, and post signage.

Last reviewed November 2026

At a Glance

Manitoba AED Laws at a Glance

Required locationsDesignated premises including schools, arenas, pools, larger fitness clubs, and transportation terminals
PlacementEnough AEDs to reach a victim and return in less than three minutes
RegistrationRegister within 30 days of installation; report moves or removal within 15 days
InspectionsMonthly inspection of the items in Schedule D, with an inspection tag on the AED
RecordsMonthly inspection records kept for 12 months
Good SamaritanProtection for users and owners, except gross negligence or failure to properly maintain

Where AEDs Are Required in Manitoba

Under The Defibrillator Public Access Act (in force January 1, 2013) and Defibrillator Public Access Regulation 150/2012, owners of designated premises must install at least one AED. Designated premises include:

  • Public and independent schools.
  • University and college campuses with an arena or gymnasium.
  • Indoor public swimming pools, hockey and skating arenas, and curling clubs.
  • Fitness clubs with 150 or more members or 20 or more hours per week of indoor group programs, and community recreation facilities with 20 or more hours per week of group programs.
  • Other listed premises, including certain transportation terminals, casinos, shelters, golf course clubhouses, and named facilities.

Owners must install as many AEDs as necessary so a bystander can retrieve one and return to the victim in less than three minutes. AEDs must be placed where the public can reach them without assistance.

Legal reference: Defibrillator Public Access Regulation 150/2012

AED equipment

AEDs installed to meet the law must be Health Canada-approved models suitable for adults and children, with an additional set of adult pads stored with the device and an indicator that activates when immediate maintenance is needed.

Registration

Owners must register each required AED, including its location, within 30 days after installation. Moves within the premises or removal must be reported as soon as practicable and no later than 15 days afterward. Shared Health maintains the registry, which is shared with 911 dispatchers.

Legal reference: The Defibrillator Public Access Act, C.C.S.M. c. D22

Maintenance, Monthly Inspections, and Records

  • AEDs must be maintained and tested according to the manufacturer’s guidelines, with maintenance records kept.
  • When the AED signals that maintenance is needed, the owner must inspect it immediately.
  • Each AED must be inspected monthly, covering the items in Schedule D of the regulation, including visibility, warning indicators, battery and pads, physical condition, and supplies.
  • An inspection tag must be attached to the AED and kept for at least 12 months, showing the location, serial number, registration number, inspection date, inspector’s name, and distributor contact information.
  • A monthly inspection record, confirming all Schedule D items were checked and noting corrective action, must be kept for 12 months.

Owners may have inspections performed by an authorized employee or agent; an outside technician is not required.

A green status indicator does not necessarily confirm that electrode pads are within their expiration date or that every component is ready for emergency use. Routine status checks are not the same as a comprehensive AED inspection. Learn more about onsite AED maintenance and inspections.

Signage

Signs must be posted at the main entrances of buildings containing an AED, next to each AED, and wherever else needed. Signs must show a heart containing a lightning bolt with “Automated External Defibrillator” or “AED”, include directions to the nearest AED, and use contrasting colours.

Training

Training is not required to use an AED in Manitoba. The Province advises that anyone can safely use an AED by following its text and voice prompts.

Legal reference: Manitoba Health: AED questions and answers

See our K–12 school AED programs.

Manitoba Good Samaritan Protection

Under the Act, a person who in good faith, voluntarily and without expectation of gain uses an AED is not liable unless grossly negligent. Owners and occupiers of premises where an AED is available are protected when acting in good faith, except for gross negligence in making the AED available, failure to properly maintain it, or premises used primarily for health care. These protections apply whether or not the AED was required by law.

Enforcement

Inspectors may enforce the Act, and contraventions are offences, with each day of a continuing offence treated as a separate offence.

Federal Requirements

Health Canada regulates AEDs as medical devices. AEDs used in Manitoba should be licensed for sale in Canada, and owners should follow the manufacturer’s instructions and respond promptly to service alerts and safety notices.

AED Service America Recommendations

Meeting minimum legal requirements is only one part of an effective AED program. AED Service America recommends:

  • Comprehensive onsite AED inspections at least annually.
  • Routine status indicator checks between inspections.
  • Tracking and timely replacement of electrode pads and batteries.
  • Documented maintenance and service records.
  • Monitoring of manufacturer recalls and safety notices.
  • CPR/AED training and documented emergency response procedures. See our AED, CPR & First Aid Training.
  • Prompt corrective action when an AED is out of service.

These are AED Service America’s professional maintenance standards, not additional legal requirements.

FAQ

Frequently Asked Questions About Manitoba AED Laws

Are AEDs mandatory in Manitoba?

Yes, at designated premises such as schools, arenas, pools, larger fitness clubs, and certain transportation terminals.

How often must AEDs be inspected in Manitoba?

Monthly, covering the items in Schedule D of the regulation, with an inspection tag and record.

Must AEDs be registered in Manitoba?

Yes. Required AEDs must be registered within 30 days of installation, and moves or removal reported within 15 days.

How long must AED inspection records be kept in Manitoba?

Monthly inspection records must be kept for 12 months.

Is CPR certification required to use an AED in Manitoba?

No. Anyone can use an AED by following its prompts.

Does failing to maintain an AED affect liability in Manitoba?

Yes. Owners and occupiers lose protection if they fail to properly maintain the AED.

How AED Service America Helps Manitoba Organizations

AED Service America provides onsite AED maintenance and management for organizations in Manitoba, helping keep AEDs Response-Ready through comprehensive onsite inspections, manufacturer-guideline maintenance, electrode pad and battery management, documented service records, and prompt resolution of equipment issues. An AED is only valuable when it is ready to perform in an emergency.