State AED Laws · Georgia

Georgia AED Laws & Requirements

Georgia requires AEDs in all public K–12 schools and sets training, maintenance, and notification requirements for AED owners. A 2026 law strengthens coordination between AED owners and 911 centers, and state law provides Good Samaritan protections for emergency AED use.

Last reviewed November 2026

At a Glance

Georgia AED Laws at a Glance

TrainingExpected AED users must complete AHA, Red Cross, or equivalent CPR/AED training
MaintenanceAEDs maintained and tested per the manufacturer’s operational guidelines
911 notificationAED owners must notify the emergency communications center of each AED’s location and type
Medical oversightPhysician or authorized person involvement required for general AED programs
SchoolsAt least one functional AED in every public K–12 school since July 1, 2025
Good SamaritanProtection except for willful or wanton misconduct

Georgia AED Owner Requirements

Under O.C.G.A. § 31-11-53.2, any person or entity that acquires an AED must ensure that:

  • Expected AED users complete American Heart Association or American Red Cross CPR and AED training, or an equivalent nationally recognized course.
  • The AED is maintained and tested according to the manufacturer’s operational guidelines.
  • A licensed physician or other person authorized by the Georgia Composite Medical Board is involved to ensure compliance with training, notification, and maintenance requirements.
  • Anyone who uses the AED activates EMS as soon as possible and reports any clinical use to the supervising physician or authorized person.
  • An agent of the emergency communications or vehicle dispatch center is notified of the AED’s existence, location, and type.

Legal reference: O.C.G.A. § 31-11-53.2

Mason Sells AED Coordination Act (SB 399, 2026)

Signed May 11, 2026, this law requires AED owners to notify 911 of their AED locations and requires 911 operators to be trained to coach callers through CPR and AED use, helping dispatchers direct callers to nearby AEDs.

Legal reference: Capitol Beat: SB 399 signed

A green status indicator does not necessarily confirm that electrode pads are within their expiration date or that every component is ready for emergency use. Routine status checks are not the same as a comprehensive AED inspection. Learn more about onsite AED maintenance and inspections.

Georgia School AED Requirements

Under O.C.G.A. § 20-2-775, as amended in 2024, every public K–12 school has been required since July 1, 2025 to have at least one functional AED on site, easily accessible during school hours and school functions. Schools must also:

  • Maintain a written emergency action plan for sudden cardiac arrest.
  • Train expected AED users and maintain the AED.
  • Designate an internal response team of at least five staff members, including team, CPR, AED, and communication leads.
  • Conduct at least two emergency action plan drills each school year, with at least one per semester.

SB 148, signed May 5, 2026, removed the requirement that a licensed physician be involved with a school’s AED program. This change applies to school AED programs; the general medical oversight provision in O.C.G.A. § 31-11-53.2 still applies to other AED owners.

Legal reference: O.C.G.A. § 20-2-775

Legal reference: SB 148 (2026), as passed

See our K–12 school AED programs.

Georgia Good Samaritan Protections

Under O.C.G.A. § 51-1-29.3, the following are immune from civil liability for good-faith emergency AED use, except for willful or wanton misconduct:

  • Any person who gratuitously and in good faith provides emergency care with an AED.
  • The owner or operator of premises or a conveyance that installs or provides an AED.
  • A physician or medical professional who authorizes, directs, or supervises AED installation at a non-medical site.
  • People who provide CPR and AED training.

Licensed professionals acting within their scope are not protected for gross negligence. AED manufacturers and off-site maintenance providers are not covered, and product liability claims are not affected.

Legal reference: O.C.G.A. § 51-1-29.3

AED Service America Recommendations

Meeting minimum legal requirements is only one part of an effective AED program. AED Service America recommends:

  • Comprehensive onsite AED inspections at least annually.
  • Routine status indicator checks between inspections.
  • Tracking and timely replacement of electrode pads and batteries.
  • Documented maintenance and service records.
  • Monitoring of manufacturer recalls and safety notices.
  • CPR/AED training and documented emergency response procedures. See our AED, CPR & First Aid Training.
  • Prompt corrective action when an AED is out of service.

These are AED Service America’s professional maintenance standards, not additional legal requirements.

FAQ

Frequently Asked Questions About Georgia AED Laws

Are AEDs required in Georgia schools?

Yes. Since July 1, 2025, every public K–12 school must have at least one functional AED on site, along with an emergency action plan, a response team, trained users, and at least two drills each school year.

Does Georgia require AED registration?

AED owners must notify the emergency communications or vehicle dispatch center of each AED’s existence, location, and type. The 2026 Mason Sells AED Coordination Act reinforces this 911 notification.

Does Georgia require physician oversight for AEDs?

General AED programs require involvement of a licensed physician or other person authorized by the Georgia Composite Medical Board. A 2026 law removed this requirement for school AED programs.

What training does Georgia require?

Expected AED users must complete American Heart Association or American Red Cross CPR and AED training, or an equivalent nationally recognized course.

What must happen after an AED is used in Georgia?

The user must activate EMS as soon as possible and report any clinical use of the AED to the supervising physician or authorized person.

Does Georgia provide Good Samaritan protection for AED use?

Yes. Good-faith AED users, AED owners and operators, supervising physicians, and trainers are protected, except for willful or wanton misconduct.

How AED Service America Helps Georgia Organizations

AED Service America provides nationwide onsite AED maintenance and management, including service coverage throughout Georgia. Our programs help organizations stay Response-Ready through comprehensive onsite inspections, manufacturer-guideline maintenance, electrode pad and battery management, documented service records, and prompt resolution of equipment issues, backed by a contractual commitment to onsite response within 48 hours for out-of-service AEDs. An AED is only valuable when it is ready to perform in an emergency.