Knowledge Center · Inspections & Readiness
Explore what a professional AED inspection can include, from battery and pad checks to documentation and device-specific procedures.
Last updated July 2026
An AED inspection checklist is a structured process used to evaluate the condition, readiness, functionality, and documentation of an Automated External Defibrillator (AED). A comprehensive inspection helps ensure the device—and every critical component associated with it—is ready to perform during a sudden cardiac arrest emergency.
One of the most common misconceptions in the AED industry is that simply checking the AED’s green status indicator is considered an inspection.
It is not.
At AED Service America, we believe understanding the difference between a verification check and a professional inspection is one of the most important aspects of maintaining an effective AED program.
Many organizations are told they should perform a “monthly AED inspection.”
In reality, most AED manufacturers distinguish between routine readiness verification and comprehensive inspections.
Routine verification is a visual confirmation that the AED appears ready for use. Comprehensive inspections follow the manufacturer’s recommended procedures and may include diagnostic testing, software interrogation, review of self-test history, and model-specific maintenance procedures.
Knowing the difference helps organizations avoid unnecessary maintenance while ensuring their AEDs remain Response-Ready.
AED Service America Best Practice: Verify your AED regularly. Inspect it professionally.
Routine verification should become part of your organization’s safety culture.
Professional inspections should follow the manufacturer’s recommendations and be performed according to the requirements of the specific AED model.
The following items should be visually verified on a routine basis according to your organization’s policies.
Verify the presence of:
Important: A readiness verification is not the same as a comprehensive inspection. Manufacturers generally do not recommend performing full diagnostic inspection procedures every month. In fact, some procedures—such as Battery Insertion Tests on certain AED models—consume battery capacity and should only be performed as recommended by the manufacturer.
A professional annual inspection evaluates much more than the visible condition of the AED.
The following elements should be included in every comprehensive inspection program.
Confirm the manufacturer, model, serial number, and device information are accurate.
Each AED manufacturer has unique inspection procedures.
Depending on the model, this may include:
These procedures verify the AED is operating according to the manufacturer’s specifications.
Every comprehensive annual inspection should document:
One of the most overlooked aspects of professional AED program management is recording battery lot numbers.
Many organizations assume that if an AED manufacturer issues a recall, the recall applies only to the AED itself.
In reality, that is often not the case.
Most AED manufacturers do not manufacture their own batteries. Instead, they purchase batteries from companies that specialize in battery manufacturing and produce batteries to the AED manufacturer’s specifications.
Those battery manufacturers assign unique production lot numbers to every manufacturing run.
If a manufacturing defect is later discovered, the recall or FDA Field Corrective Action often applies only to a specific production lot—not every battery in service.
If an organization records only the AED serial number, there is no efficient way to determine which AEDs contain the affected batteries.
At AED Service America, recording battery lot numbers is considered a best practice.
By maintaining an accurate database of every battery installed in every AED we manage, we can immediately identify affected batteries whenever a manufacturer issues a recall or Field Corrective Action.
Instead of manually inspecting hundreds—or even thousands—of AEDs to determine where recalled batteries may be installed, we can immediately identify the affected devices and dispatch technicians to replace only the batteries that require replacement.
That level of preparedness helps keep every AED Response-Ready while dramatically reducing response time during a recall.
Every comprehensive annual inspection should also document:
Just as AED manufacturers generally do not manufacture their own batteries, they also generally do not manufacture their own electrode pads.
Instead, AED manufacturers purchase electrode pads from specialized medical manufacturers that produce pads to the AED manufacturer’s specifications.
Like batteries, every production run of electrode pads is assigned a unique manufacturing lot number.
If a manufacturing issue is identified, the recall or FDA Field Corrective Action frequently applies only to specific production lots.
Organizations that record only the AED serial number have no practical way to determine which AEDs contain the affected pads.
By recording electrode pad lot numbers during every annual inspection, AED Service America maintains a complete history of the critical components installed in every AED we manage.
If a manufacturer later announces that a particular production lot has been recalled, we can immediately identify every affected AED within our managed accounts and dispatch technicians to replace the recalled pads.
Rather than spending days or weeks trying to determine where affected pads may be located, we already have the information available.
This level of component tracking is one of the defining characteristics of professional AED program management.
Review current manufacturer recalls affecting:
Not every safety issue results in a product recall.
Manufacturers may also issue FDA Field Corrective Actions requiring inspections, software updates, replacement components, or other corrective measures.
These notices should be reviewed during every annual inspection.
Verify warranty status and document any devices approaching the end of manufacturer support.
Verify:
Verify all emergency supplies are present, clean, and within their expiration dates.
Evaluate conditions that may affect AED performance, including:
Confirm the AED is:
Photographic documentation should record:
Photographs provide valuable quality assurance and historical documentation.
A professional inspection does not end when the technician leaves the facility.
Every inspection should create a permanent record that documents:
Many organizations think of inspection documentation as paperwork.
We view it as one of the most valuable components of a professionally managed AED program.
Every inspection generates information that becomes part of the permanent history of that AED.
Maintaining accurate records allows organizations to:
For organizations managing dozens—or even thousands—of AEDs across multiple facilities, effective data management transforms what could otherwise become an overwhelming administrative challenge into an organized, searchable, and proactive maintenance program.
At AED Service America, we believe managing the information surrounding an AED is just as important as inspecting the AED itself.
We don’t simply inspect AEDs.
We manage every piece of information that helps keep them Response-Ready.
After inspecting thousands of AEDs across the United States, we’ve learned that many organizations mistakenly believe a green Ready indicator means their AED program is fully maintained.
In reality, the Ready indicator confirms only that the AED has passed its automatic internal self-tests.
It does not verify:
Professional AED program management requires much more than checking a green light.
A professional AED inspection is far more than a checklist.
It is a comprehensive process that combines manufacturer recommendations, diagnostic testing, component tracking, recall management, documentation, data management, and preventive maintenance into a complete AED program.
At AED Service America, we believe organizations deserve more than a vendor who simply checks a box.
They deserve a partner committed to protecting their people through education, transparency, and professional AED program management.
If you would like more information about this important topic or have questions about your organization’s AED program, we’re here to help.
Our goal is to educate first. Even if you never become a client, we’re happy to answer your questions and help you make informed decisions about your AED program.
Email us anytime at support@aedserviceamerica.com, and one of our AED specialists will be happy to assist you.
Educational disclaimer: AED maintenance requirements, self-test capabilities, replacement intervals, and storage limits vary by manufacturer and model. Always follow current manufacturer instructions, applicable safety notices, and relevant legal requirements.
Keep Reading

Learn the difference between routine AED status checks and comprehensive inspections, and when additional inspections may be needed.
Read article
Learn why AED manufacturer audits, component tracking and warranty status matter for continued safe service.
Read articleAED Service America provides nationwide onsite AED maintenance and management, including comprehensive inspections, manufacturer audits, battery and electrode pad management, recall monitoring and ongoing program oversight.
Phone: 860-970-3250
Email: support@aedserviceamerica.com